What is a corrosion inhibitor?
A corrosion inhibitor is a chemical added in small amounts to a fluid to slow the corrosion of metal it touches. In oil, gas and refining, the main threats are CO₂ (sweet), H₂S (sour), oxygen, chlorides and acids.
Products are formulated blends of active ingredients such as imidazolines, fatty amines, quaternary ammonium compounds or neutralising amines, in water or hydrocarbon solvents. There is no single CAS number; each product has its own SDS.
Where are corrosion inhibitors used?
Corrosion inhibitors protect oil and gas wells, flowlines and export pipelines in oil and gas, crude-unit overheads and condensate systems in refining, acid used for well stimulation and pickling, and cooling and boiler water systems.
How are corrosion inhibitors produced?
Corrosion inhibitors are made by synthesising active molecules and blending them into a deliverable product.
- Imidazolines are made by condensing fatty acids, such as tall-oil fatty acid, with polyamines; they can be quaternised or salted for water solubility.
- Amines such as morpholine, cyclohexylamine and fatty amines are made by chemical synthesis.
- Actives are blended with solvents, surfactants and sometimes synergists such as thiols, to suit the fluid and injection point.
- Each lot is tested for active content, density, pH or amine value, appearance and pour point.
Corrosion inhibitor types
The table compares the main types; each is then explained with its typical uses. The product is selected for the fluid, temperature and metallurgy.
| Filming (imidazoline / amine) | Neutralising amines | Acid inhibitors | Water-system inhibitors | |
|---|---|---|---|---|
| Chemistry | Imidazolines, fatty amines, quats | Morpholine, cyclohexylamine, MEA, DEAE | Quats, acetylenic alcohols, surfactants | Azoles, phosphates, molybdate |
| Solubility | Oil-soluble, water-dispersible or water-soluble | Water- and steam-volatile | Acid-soluble | Water-soluble |
| Typical dose | about 10–100 mg/L | to target pH | about 0.2–2 % in acid | per programme |
| Best for | Wells, flowlines, pipelines | Crude overheads, condensate | Acidising, pickling, cleaning | Cooling and closed loops |
Filming inhibitors (imidazolines and amines)
They adsorb on steel and form a thin, hydrophobic film that keeps water and corrosive gases away from the surface.
- CO₂ and H₂S corrosion in wells and flowlines
- Multiphase and export pipelines
- Refinery overhead filmers
- Batch treatment of tubing
Neutralising amines
Volatile amines that travel with steam or vapour and raise the pH of condensing water.
- Crude-unit overhead pH control
- Steam-condensate return lines
- Vacuum and fractionator overheads
Acid corrosion inhibitors
They protect steel while strong acids dissolve scale or rock.
- Matrix acidising with hydrochloric acid
- Steel pickling
- Chemical cleaning of boilers and exchangers
Water-system inhibitors
Programme chemicals for cooling and closed water circuits, often combined with scale inhibitors.
- Copper protection with azoles
- Closed-loop molybdate or nitrite programmes
- Open cooling towers
Typical analysis (filming inhibitor)
| Parameter | Typical value |
|---|---|
| Appearance | Amber to dark brown liquid |
| Active content | about 20–50 % |
| Density (20 °C) | about 0.90–1.05 g/cm³ |
| Pour point | ≤ −20 °C (winter grades lower) |
| Flash point | per solvent system |
| Solubility | per product: oil, water or dispersible |
Each product has its own TDS. The binding specification is the one in our offer and in the Certificate of Analysis for each lot.
Physical properties
| Property | Value |
|---|---|
| Form | Liquid concentrate |
| Viscosity | Low to medium; pumpable through injection quills |
| Compatibility | Tested with other production chemicals and elastomers |
| Emulsion tendency | Checked so it does not stabilise oil–water emulsions |
| Shelf life | about 12–24 months in closed containers |
Chemical properties
Performance is proven with laboratory tests such as wheel, bubble and rotating-cylinder-electrode tests, following methods from AMPP (formerly NACE).
- Filming inhibitors adsorb through nitrogen head groups and form a barrier with their hydrocarbon tails.
- Neutralising amines react with acids such as HCl and CO₂ in condensing water to raise pH.
- Partitioning between oil and water decides where the inhibitor acts; it is measured during selection.
- Many actives are corrosive amines (H314) and toxic to aquatic life (H400, H410); solvent carriers may be flammable.
Corrosion inhibitor applications
Oil and gas production
Continuous injection into wells and flowlines controls CO₂ and H₂S corrosion; batch treatments protect tubing. Methanol for hydrate control is often injected alongside.
Pipelines
Inhibitors protect export pipelines carrying wet gas, crude and produced water and are monitored with coupons and probes.
Refinery overheads
Neutralisers and filmers protect crude- and vacuum-unit overheads from HCl and other acids.
Acidising and cleaning
Acid inhibitors protect tubing and equipment during acid jobs and chemical cleaning.
Steam and water systems
Neutralising and filming amines protect condensate lines; water inhibitors protect cooling and closed loops.
Main corrosion inhibitor supplier countries
Corrosion inhibitors are formulated by oilfield and water-treatment chemical companies in the United States, Europe, the Middle East, China and India, close to their customers.
Corrosion inhibitors in Turkey
Turkey’s refineries, gas pipelines, power plants and industry use corrosion inhibitors, supplied by international and local chemical-service companies.
Mercafons supplies oilfield, refinery and acid corrosion inhibitors through its Istanbul office, with selection testing and CoA for each lot.
Corrosion inhibitor price
The corrosion inhibitor price depends on actives, active content, solvent system and volume; compare cost per day of protection at the required dose, not price per kg. Request a quote with fluid data.
Corrosion inhibitor packaging
Packages carry product name, lot number, net weight and hazard labels.


Shipment
Many corrosion inhibitors are dangerous goods, typically Class 8 (corrosive) and/or Class 3 (flammable), depending on actives and solvent. Check the SDS of the product supplied. A 20 ft container holds about 16–20 t. See logistics. HS code: 3824.99.
Storage and safety
Storage
Store in closed containers in a ventilated, bunded area, away from oxidisers and acids, and within the temperature range on the TDS. Protect water-based grades from frost.
Safety
Wear chemical goggles, nitrile gloves and protective clothing; amines can cause burns. Prevent release to drains and water.
Corrosion inhibitor FAQ
How is the right corrosion inhibitor chosen?
From fluid analysis, temperature, flow and metallurgy, then confirmed with laboratory tests. Our engineers can support selection.
What is the difference between filming and neutralising amines?
Filming amines form a protective film on metal; neutralising amines raise the pH of condensing water.
How is inhibitor performance monitored?
With corrosion coupons, electrical-resistance or LPR probes and iron counts in produced water.
Can corrosion inhibitors cause emulsions?
Some can; compatibility and emulsion tests are part of selection.
Are corrosion inhibitors dangerous goods?
Often yes, Class 8 and/or Class 3; it depends on the product.
Corrosion inhibitor documents: MSDS, TDS and CoA by type
Each corrosion inhibitor has its own SDS and TDS because actives and solvents differ. See technical documents.
Filming inhibitors
Oil- and water-soluble grades.
Neutralising amines
Overhead and condensate.
Acid inhibitors
Acidising and pickling.
Last reviewed: November 2026